Varec 4532 Instruction Manual Page 27

  • Download
  • Add to my manuals
  • Print
  • Page
    / 70
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 26
Varec, Inc. 17
4532 Mounting
5.2.3 Anchor weight method
The flexible tube is stabilized by an anchor weight:
Figure 5-6: Anchor weight application
Note! Make sure to put the anchor weight on the tank bottom. When installing with the sus-
pended anchor weight, please use the anchor weight at a maximum of 16 kg. More
weight may cause internal breaking in the flexible tube.
Caution! The flexible tube must be lowered carefully without bending too much and scratching
at the inner edge of the nozzle hole.
1. Insert a gasket and lower the flexible tube from the nozzle on the tank top.
2. Rotate the 4532 ATC so that you can set up the cabling in the most convenient way.
3. Tighten the tensioning wire between the lower end of the flexible tube and the
anchor weight.
4. Wrap the tensioning wire twice around a hole on the bottom hook, tighten it and
wrap a provided wire around it (see Figure 5-7 on page 16).
5. Fix the mounting flange of the 4532 ATC to the nozzle on the tank top using bolts.
Electrical compartment
Cable entry as specified
Flange
Flexible tube
approx.500 mm
From tank bottom to
element position #1
Tank height
Nozzle heigh
t
Clearance below
bottom hook
Ø26 mm(1.02")
400 mm (15.57")
(20")
Tank bottom
Ø120 mm(4.72")
222 mm(8.74")
1000mm(39.37")
41mm(1.61")
Page view 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 69 70

Comments to this Manuals

No comments